Overview
Transcom T5000 Series vector network analyzer offers the high RF performance, wide frequency range and versatile functions. The T5000 series is the economic solution for manufacturing and R&D engineers evaluating RF components and circuits for frequency range up to 8GHz.
Key Features |
- Frequency Range:300kHz~1.3GHz/3GHz/8GHz(T5113A/ T5230A/ T5280A)100kHz~8GHz(T5480)
- Dynamic Range:>125 dB (IFBW=10 Hz), 130 dB typical
- Low Noise Level:<-120 dB (IFBW=10 Hz)
- Low Trace Noise:1 mdB rms (IFBW=3 kHz)
- High Measurement Speed:100 μs/point (IFBW=30 kHz)
- High Effective Directivity:>45 dB
- Remote Control: LAN/GPIB/USB
- Very Low Power Consumption:60W
- “One-Key-Test” Solution
|
Specification |
-
Measurement Range |
Product Model |
T5480A |
T5280A |
T5230A |
T5113A |
Impedance |
50Ω |
50Ω |
50Ω,75Ω1 |
50Ω,75Ω1 |
Test Port Connector |
N-type, female |
Number of Test Ports |
4 |
2 |
Frequency range |
100kHz~8.0GHz |
300kHz~8.0GHz |
300kHz ~ 3.0GHz |
300kHz~1.3GHz |
Full CW Frequency Accuracy |
±5×10-6 |
Frequency Resolution |
1Hz |
Number of Measurement Points |
2 ~ 10001 |
2 ~ 1601 |
Measurement Bandwidths |
1Hz to 30kHz (in 1 / 1.5 / 2 / 3 / 5 / 7 steps) |
1Hz to 30kHz (in 1 / 3 steps) |
Dynamic Range |
115 dB, typ. 125 dB
(100kHz~300kHz)
135 dB, typ. 140 dB
(300kHz~8GHz) |
125dB, typ.130dB |
Measurement Parameters |
S11,S21, S31,S41
S12,S22,S32,S42
S13,S23,S33,S43
S14,S24,S34,S44 |
S11, S21, S12, S22 |
S11, S21, S12, S22 |
S11, S21 |
1Use 75 connector via adapter
Effective System Data |
Product Model |
T5480A |
T5280A |
T5230A |
T5113A |
Effective Directivity |
46 dB |
45 dB |
Effective Source Match |
40 dB |
40 dB |
Effective Load Match |
46 dB |
45 dB |
NA |
1 Applies over the temperature range of 23°C ± 5°C after 40 minutes of warming-up, with less than 1°C deviation from the full two-port calibration temperature, at output power of -5 dBm and IF bandwidth 10 Hz.
Measurement Accuracy |
Product Model |
T5480A |
T5280A |
T5230A |
T5113A |
Accuracy of Transmission Measurements (magnitude / phase) |
|
|
+5dB to +15dB |
0.2dB/2º |
0.2dB/2º (+10dB to +13dB) |
-50dB to +5dB |
0.1dB/1º |
0.1dB/1º (-50dB to +10dB) |
-70dB to -50dB |
1.5dB/10º(100kHz~300kHz)
0.2dB/2º(300kHz~8GHz) |
0.2dB/2º |
-90dB to -70dB |
1.0dB/6º(300kHz~8GHz) |
1.0dB/6º |
Accuracy of Reflection Measurements (magnitude / phase) |
-15dB to 0dB |
0.4dB/3º |
-25dB to -15dB |
1.0dB/6º |
1.5 dB/7º |
-35dB to -25dB |
3.0dB/20 |
4.0 dB/22º |
Trace stability |
Trace Noise Magnitude (IF bandwidth 3 kHz) |
1mdBrms
(100kHz~300kHz)
1mdBrms
(300kHz~8GHz) |
1mdB rms |
2 mdB rms |
Temperature Dependence (per one degree of temperature variation) |
0.02 dB |
Measurement Speed |
Product Model |
T5480A |
T5280A |
T5230A |
T5113A |
Measurement Time Per Point |
100ms |
125ms |
150 ms |
Source to Receiver Port Switchover Time |
< 10ms |
NA |
Typical Cycle Times Versus Number of Measurement Points(IFBW 30kHz) |
51 201 401 1601 |
One-Path Two-Port Calibration(300kHz~1.3GHz) |
NA
|
9ms 31ms 60ms 235ms |
Uncorrected(300kHz~10MHz) |
13.1ms 51.3ms 102.3ms 408.3ms |
13ms 52ms 104ms 413ms |
NA |
Full Two-Port Calibration(300kHz~10MHz) |
45.5ms 122.0ms 230.5ms 840.5ms |
46ms 123ms 226ms 844ms |
NA |
Uncorrected(10MHz~3GHz/8GHz) |
6.5ms 21.1ms 40.5ms 157.7ms |
7ms 27ms 53ms 207ms |
NA |
Full Two-Port Calibration 10MHz~3GHz/8GHz) |
32.4ms 61.7ms 100.3ms 333.0ms |
34ms 73ms 125ms 434ms |
NA |
Test Port Output |
Product Model |
T5480A |
T5280A |
T5230A |
T5113A |
Match (W/O System Error Correction) |
18 dB |
15dB |
20dB |
Power Range |
300kHz~1.3GHz/3GHz/6GHz |
-60dBm to +10dBm
(100 kHz – 6 GHz) |
-60dBm to +5dBm |
-55dBm to +10dBm |
-55 dBm to +3 dBm |
6GHz~8GHz |
-60dBm to +5dBm |
NA |
Power Accuracy |
±1.5 dB |
±1.5 dB |
±1.0dB |
±1.5 dB |
Power Resolution |
0.05dB |
Test Port Input |
Product Model |
T5480A |
T5280A |
T5231A |
T5113H |
Match (W/O System Error Correction) |
18 dB |
25dB |
30dB |
Damage Level |
+26dBm |
Damage DC Voltage |
+35V |
Noise Level (IF Bandwidth 10 Hz) |
< -105dBm(100 kHz – 300kHz)
< -125dBm(300 kHz – 8GHz) |
< -125dBm |
< -120dBm |
< -127dBm |
General Data |
Display |
10.4 inch TFT color LCD, touch screen |
External Trigger Input Connector |
BNC female, Input level range: 0 to +5 V |
External Reference Input |
BNC female; 10 MHz; 2 dBm ± 3 dB (T5480A)
BNC female; 10 MHz; 2 dBm ± 2 dB(T5280A/T5230A/T5113A) |
External Reference Output |
BNC female; 10 MHz; 3 dBm ± 2 dB (T5480A)
BNC female; 10 MHz; 2 dBm ± 2 dB(T5280A/T5230A/T5113A) |
VGA Video Output |
15-pin mini D-Sub; female; driving the VGA compatible monitors |
GPIB Connector (Optional) |
24-pin D-Sub (type D-24), female; compatible with IEEE-488 |
USB Connector |
Female; provides connection to printer, ECal module, USB storage |
LAN Connector |
10/100/1000 Base T Ethernet, 8-pin |
Operating Temperature Range |
+5°C ~ +40°C |
Storage Temperature Range |
-45°C ~ +55°C |
Humidity |
90% (25°C) |
Atmospheric Pressure |
84 to 106.7 kPa |
Calibration Interval |
3 yr |
Power Supply |
220 ± 22 V (AC), 50 Hz |
Power Consumption |
60W |
Dimensions (W × H × D) |
440 ×231 ×360 mm |
Weight |
13kg(T5480A)
12.5 kg (T5280A/T5230A)
10kg (T5113A) |
|
|