Digital Multimeter
Quick Details |
Place of Origin: China (Mainland)
Brand Name: CUSTOM
Model Number: M-08L
Measuring Current Range: DCA: 400mA / ACA: 400 mA
Measuring Voltage Range: DCV: 4V, 40V, 400V, 600V / ACV: 4V, 40V, 400V, 600V
Measuring Resistance Range: 400/4k/40k/400k/4M/40M Ω
Measuring Capacitance Range: 40nF, 400nF, 4uF, 40uF, 200uF
Measuring Inductance Range: None
Operating Temperature: 0 to +40 deg.C, <75% RH (No condensation)
Dimensions: W60 x H125 x D23.7 mm
Design and Development: Japan
Continuity Buzzer: yes
Diode Test: yes
Capacitance check: yes
Frequency Check: yes
Duty check: yes
|
Feature |
Pocket-sized digital multimeter with A/D converter IC
Poor contact hardly occurs in the test leads plated with gold
Measurement functions: DC/AC voltage, resistance, Continuity check, diode test, frequency measurements, duty cycle checks, relative function and capacitor check
Backlight
Auto Power Off (30min and Releasable)
Main Unit: IEC 61010 600V CATII, 300V CATIII
|
Specifications |
Display |
LCD, maximum display “4000” equipped with backlight functionality |
Over range display |
"OL" Indication only |
Low battery indication: |
Low Battery icon |
Polarity display: |
Only “-” indication |
Measurement functions |
Direct voltage, alternating voltage, resistance, continuity checks, diode tests, frequency, duty cycle checks, capacitor and relative |
Sampling: |
3 times/sec |
Operating environment |
0 °C-+40 °C, <75%RH (No condensation) |
Storage environment: |
-10 °C-+50 °C, <75%RH (No condensation) |
Power supply: |
2x LR-44 (1.5V) lithium batteries |
Dimensions and weight: |
60(W)×125(H)×23.7(D)mm, Approx. 118g |
Accessories: |
Operating instruction |
Safety: |
Complies with IE61010-1, CAT.II 600V |
ELECTRICAL PERFORMANCE
Condition: 23°C±5°C 75%RH or less
Accuracy: ±(_% reading value_minimum number of digits)
DC voltage measurement, AC voltage measurement
|
Range |
Resolution |
Accuracy |
Input resistance |
DCV*1 |
4V
40V
400V
600V |
1mV
10mV
100mV
1V |
±(1.3%+3dgt) |
10MΩ |
ACV *2 |
4V
|
1mV
|
±(2.3%+10dgt) |
10MΩ |
40V
400V
600V |
10mV
100mV
1V |
±(2.3%+5dgt) |
*1: Maximum input voltage: 600V DC
*2: Maximum input voltage: 600V AC rms
Resistance measurement, Capacitor check
|
Range |
Resolution |
Accuracy |
Ω *3 |
400Ω
4kΩ
40kΩ
400kΩ
|
0.1Ω
1Ω
10Ω
100Ω
|
±(2.0%+5dgt) |
4MΩ |
1kΩ |
±(5.0%+5dgt) |
40MΩ |
10kΩ |
±(10.0%+5dgt) |
Capacitor check *4 |
40nF
400nF
4μF
|
10pF
0.1nF
1nF
|
±(5.0%+10dgt) |
40μF
200μF |
10nF
100nF |
±(10.0%+15dgt) |
*3: Maximum input voltage: 250V AC rms
*4: Maximum input voltage: 250V DC/AC rms
Continuity check
Diode check
Range |
Resolution |
0.1—2V |
1mV |
Frequency measurement
Range |
Resolution |
Accuracy |
Condition |
40Hz
400Hz
4kHz
40kHz
300kHz |
0.01Hz
0.1Hz
1Hz
10Hz
100Hz |
±(0.7%+5dgt) |
10Vrms or higher with
frequency up to 40kHz
40Vrms or higher with
frequency of 100kHz or higher
|
Maximum input voltage: 250V DC/AC rms
For frequency between 40kHz and100kHz , the measurable voltage varies depending on the measured frequency.
DUTY measurement
0.1-99.9%
Accuracy: ±(1.0%+5dgt)
Frequency character: 0-200kHz |
|
|