Key product |
3 isolated analog input channels, 50 kS/s per channel simultaneous sample rate 22 Arms continuous, ±30 Apeak input range, 24-bit resolution (AC signals only) Designed for 1 A/5 A nominal CTs Up to 300 Vrms Channel-to-Earth and 480 Vrms Channel-to-Channel CAT III isolation Ring lug connectors for up to 10 AWG cables -40 °C to 70 °C operating temperature, 5 g vibration, 50 g shockPower quality monitoring and metering Utility pole-mounted smart switches Utility pole-mounted smart grid reclosers Substation merging units Industrial machine measurements Health monitoring Predictive maintenance and prognosis |