Key performance specifications
      AC/DC measurement capabilities

  • DC – 100 MHz, Current Probe Amplifier (TCPA300) uses:
    • DC – 100 MHz, 30 A DC (TCP312A)
    • DC – 50 MHz, 50 A DC (TCP305A)
    • DC – 15 MHz, 150 A DC (TCP303)
  • DC – 50 MHz, Current Probe Amplifier (TCPA400) Uses:
    • DC – 2 MHz, 750 A DC 1 (TCP404XL) (500 A DC Continuous)

 

Key Features 
  • Automatic scaling and units 2 – Oscilloscope on-screen readout of magnitude and amps reduces measurement errors with no more hand calculations
  • AC/DC input coupling
  • Low insertion impedance reduces device under test loading
  • Split-core construction allows easy circuit connection
  • Status indicators provide visual operating status and notification of potential error conditions – degauss, probe open, overload, not terminated into 50 Ω, noncompatible probe type
  • Low DC drift and noise allows improved low-level current measurements
  • 3rd party safety certification

 

Applications
  • Development and analysis solutions for designers, installers,
  • and service personnel in telecom, data comm, computer, and
  • semiconductor power electronics environments for:
  • Power supplies (switching and linear)
  • Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS,
  • BJTs)
  • Power inverters/converters
  • Electronic ballasts
  • Industrial/consumer electronics
  • Mobile communications (phone, satellite, relay stations)
  • Motor drives
  • Transportation systems (electronic vehicles, electric trains, locomotives, avionics)

 

Reviews

There are no reviews yet.

Be the first to review “Tektronix TCP300 and TCP400 Series AC/DC Current Probes”