Key product
Input

Maximum drive voltage, external power

50 V DC

Maximum drive current
Per channel

600 mA

Per module

25 A

Internal drive power

5 V at 1.25 A

12 V at 0.5 A

Dynamic
Single-channel operate time at 25 °C

60 μs, typical

Channel-to-ground resistance (RDSon)
0 mA to 600 mA drive current

0.280 Ω, maximum

Channel off drain current (IDSS)
13 V drive voltage

50 μA, typical

25 V drive voltage

200 μA, typical

Trigger
Input trigger
Sources

PXI trigger lines <0…7>

Minimum pulse width

150 ns