Key product
Line and Load Regulation
Line Regulation[15] (per volt of change in auxiliary power input) ± (% of output + offset)
Voltage, channel 1 and 20.01 + 1 mV

Current, channel 1 and 2

0.01 + 0.02% of range

Load Regulation
Voltage (% of voltage range, per amp of output load, measured at output channel terminals)
Channel 0

0.42%

Channel 1 and 2

0.1%

Current (% of current range, per volt of output change)
Channel 0

0.02%

Channel 1 and 2, 1 A range

0.007%

Channel 1 and 2, 20 mA range

0.003%

Measurement Timing Characteristics
Sample rate
Default

300 S/s, nominal

Maximum

3,000 S/s, nominal

Absolute Maximum Limit
Maximum Voltage
Channel-to-COM

14 VDC over rated output, CAT I

Cascading multiple channels, channel-to-chassis ground

60 VDC max

Protection
Output channel protection
Overvoltage

Tolerates 14 VDC over rated output

Overcurrent or reverse voltage

Fused

Overtemperature

Automatic shutdown